Reports until 11:27, Wednesday 15 May 2024
GQuEST Output Filter Cavities
Torrey Cullen - posted 11:27, Wednesday 15 May 2024 (11575)
Filter Cavity Mirror Naming Convention

There has been some confusion on the super optics part labels and their placement position in the filter cavities. This post should clarify that for my own benefit and others. Below is a list of mirrors, their printed labels, reflectivity, and curvatures, according to https://wiki.mccullerlab.com/DCC/S2400001.

Part Label Curvature 1550 775 Quantity
M1 Flat 883ppm HR 24
M2 Flat HR 1% 16
M3 1.6m HR 1% 8
M4 3m HR 1% 8

Note that the part label M1, M2, etc, does not correspond to its position in a filter cavity. The proposed configuration for the first filter cavity should be (according to labpic_w_labels_updated.png):

 

 