Reports until 12:35, Friday 18 April 2025
Vacuum Systems General (GQuEST)
Daniel Grass - posted 12:35, Friday 18 April 2025 - last comment - 14:44, Friday 18 April 2025(12253)
Nitronic 60 1/4-20 1/4 long helicoils and custom 1/4-100 Bushings Cleaned and are Baking Out

I cleaned 15 Nitronic 60 1/4-20 1/4 long helicoils and 4 of the 5 custom 1/4-100 bushings. I used the standard 1:30 simple Green:DI water, DI water, then isopropanol baths and sonication for 10 minutes each. I am currently baking them out at 200°C for 48 hours.

Comments related to this report
Daniel Grass - 14:44, Friday 18 April 2025 (12254)

200°C reached at 2:40 PM.